Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b The Air conditioning unit in the machine room is not cooling the machine room. The controller states the equipment is not designed to operate at temperatures higher than 89 degrees.
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) x The car door restrictor shall work. 7/1/2019
MO Minimum : Elevators (I) - Pits (I)5 Repair or replace ladder in pit. Rusted and broken rungs.
MO Minimum : Elevators (I) - Pits (I)1 The pit needs to be cleaned. Elevator pits shall be kept clean, dry, and free of debris.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars The car top needs to be cleaned. Car tops shall be kept clean of dust and debris.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Telephone in car doesn't work. Phone line dead to elevator controller. 6/1/2021