MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days)
|
x
|
|
Telephone in car doesn't work. Phone line dead to elevator controller.
|
6/1/2021
|
|
A17.1-1996 : Elevators
|
1.18 - Restricted opening of car or hoistway doors
|
1001.2(a)(18)
|
x
|
|
The car door restrictor shall work.
|
7/1/2019
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.9 Cleaning of Top of Cars
|
|
|
The car top needs to be cleaned. Car tops shall be kept clean of dust and debris.
|
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)5
|
|
|
Repair or replace ladder in pit. Rusted and broken rungs.
|
|
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
The pit needs to be cleaned. Elevator pits shall be kept clean, dry, and free of debris.
|
|
|
A17.1-1996 : Elevators
|
2.6 - Ventilation
|
101.5b
|
|
|
The Air conditioning unit in the machine room is not cooling the machine room. The controller states the equipment is not designed to operate at temperatures higher than 89 degrees.
|
|