Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (I) - Pits (I)5 No No Repair or replace ladder in pit. Rusted and broken rungs. 7/16/2026
MO Minimum : Elevators (I) - Pits (I)1 No No The pit needs to be cleaned. Elevator pits shall be kept clean, dry, and free of debris. 7/16/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No The car top needs to be cleaned. Car tops shall be kept clean of dust and debris. 7/16/2026
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b No No The Air conditioning unit in the machine room is not cooling the machine room. The controller states the equipment is not designed to operate at temperatures higher than 89 degrees. 7/16/2026
A17.1-2016 : Elevators 3.20 - Governor rope 8.6.3.4 Yes Yes The governor rope is severely rusted from being submerged in water. The number of broken strands per lay exceeds the maximum allowable amount. Replace governor rope. (Red Tag) 8/27/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No All 5-year and annual tests still need to be performed
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) Yes No The car door restrictor shall work. 7/1/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Telephone in car doesn't work. Phone line dead to elevator controller. 6/1/2021