Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No Plastic covers shall be placed on the car light bulbs to protect people from glass in case of breakage or replace to plastic ceiling tiles 5/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Door Systems 8.6.4.13 (Re-Inspection) Yes No Door restrictor shall be made operable 5/22/2023
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 Yes Yes The safeties are not working properly. Elevator Red Tagged. 8/14/2024
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) Yes No Car door restrictor not working. 4/17/2019
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors Yes No Car door restrictor not working. 8/26/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Safeties shall be tested with full load. 8/14/2024
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) Yes Yes Hoist ropes must be replaced as they have significant rouging and rope diameter is below the minimum code required.
A17.1-1996 : Elevators 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions 1001.2(e)(10) Yes Yes safety rope pullout exceeded the distance allowed
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures Yes No Fire service operation still needs to be tested.
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current State operating certificate shall be displayed in the machine room 8/7/2026