MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
12/30/2025
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
12/30/2025
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
12/30/2025
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)1
|
|
|
Cab ventilation fan is not operational and shall be repaired.
|
1/12/2021
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
x
|
|
Engaging car-top inspection with the controller inspection knife switch shall not bypass hall door interlocks or the car gate switch.
|
5/18/2020
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
|
|
The elevator machine room door to the roof shall be repaired to be self-closing/self-locking and shall be operable from the interior space without the use of a key.
|
|
|
A17.1-2016 : Elevators
|
3.20 - Governor rope
|
8.6.3.4
|
x
|
|
The elevator safety pull out connection to the governor rope has been replaced with fist grip type attachment devices that are now impeding the pull out of the elevator car safeties. The governor rope attachments shall be replaced with a code conforming attachments that do not impede the actuation of the elevator car safeties. Repair and reinspection required in 30 days or the elevator shall be removed from service.
|
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
The emergency car lighting is not operational. The fixture shall be repaired to operate. Reinspection required.
|
|