Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.4 x 2.2.4.5 - Walk in pit door shall be self-closing and self-locking with means to disable service car operation before entering pit. 10/19/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/19/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 9/19/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/19/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)1 Cab ventilation fan is not operational and shall be repaired. 1/12/2021
A17.1-2016 : Elevators 2.1 - Access to machine space 2.7.3.3 x Install proper steps from controller level to machine level. 10/19/2023
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device x x Smokes were tested with magnet but must be tested by fire device company with smoke when all units are ready for acceptance test. 10/19/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The inspection was not completed due to problems at the time. The following tests still need to be completed: Fire service, unintended movement, door pressure, lighting & phone. Re-inspection required 11/18/2024