Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.13 - Governor, Overspeed Switch, and Seal 8.6.4.12 x Remote governor trip not functioning. 11/30/2021
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x Provide testing of the elevator on emergency power. 9/10/2024
A17.1-2016 : Elevators 2.29 - Car and counterweight safeties 8.6.4.20.1 x Provide Cat 5 testing of the car safeties. Record slide. Check rails for dressing. 9/10/2024
A17.1-2016 : Elevators 3.17 - Door and gate equipment 8.6.4.13 Observed several bottom door guides (on different floors) don’t have fire tabs bent down, make so.
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.2 through 2.27.8 Firefighter Service x x On Phase II operations, door close function not working. Car removed from service. 9/10/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x Provide testing of the elevator on emergency power.
A17.1-2016 : Elevators 2.29 - Car and counterweight safeties 8.6.4.20.1 x Provide Cat 5 safety test, record slide.
A17.1-2016 : Elevators 3.17 - Door and gate equipment 8.6.4.13 Observed bottom door guides ( on several floors) don’t have fire tabs bent down, make so.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Clean the car top.
MO Minimum : Elevators (I) - Pits (I)1 Clean upper and lower pits.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Clean car top.
MO Minimum : Elevators (I) - Pits (I)1 Clean upper and lower pits.