Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 can not read the markings on the fire service phase 1 keyswitch collar, replace the collar
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 Perform monthly fire service test and post test log in the machine room
A17.1-1996 : Elevators 3.17 - Door and gate equipment 111 could not test the gate switch, the button to diable the door operator to test the gate switch did not work
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 the next 5 year test on the overspeed valve will be in 2025 10/12/2021
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State operating certificate in the machine room expired in 2019, update with current state operating certificate when received
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate on display in the elevator machine room expired in 2019, update with the current certificate when received from the state
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the copy of the state operating certificate in the machine room is to be updated annually