Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The following tests need to be performed to complete the 5 year inspection: 125% brake / lower & hold, car safeties, car buffer and counterweight buffer. Re-inspection required 6/26/2023
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Suspension ropes are rouged and undersized, need to replace suspension ropes. Re-inspection required
A17.1-1996 : Elevators 2.3 - Lighting and receptacles 101.5a Lighting Repair machine room lighting above machine and in front of controller
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room