Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)4 x Provide bottom door guides on "B" floor hoistway door. 9/15/2021
MO Minimum : Elevators (A) - Hoistways (A)10 Provide code compliant hoistway access. 9/15/2021
MO Minimum : Elevators (A) - Hoistways (A)16 Remove broken traveling cable in hoistway that's still attached to the bottom side of cab
MO Minimum : Elevators (A) - Hoistways (A)1 x Existing hoist way doors require safety glass installed, provide proof that existing pane glass in hoist way door is CODE compliant. Numerous floors. 9/5/2023
MO Minimum : Elevators (A) - Hoistways (A)1 x Hoistway door sill catch on bottom floor needs to be secured to sill. 9/5/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)10 Car Floors Provide means to substantially level floor. Pull out hole creates a tripping hazard. 9/15/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 Provide means to secure the emergency exit. 9/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Replace or repair all hoistway door glass vision panels as needed. 9/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Repair or replace slide guide on left side of car. Guide is worn out and barely touches rail
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces Machine room shall be kept clean & free of debris and trash
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Provide a current tested fire extinguisher in the machine room. 9/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Several floors have the wired class panels, need to replace with solid glass, that is not etched or labeled. Provide proper labeling or replace if glass does not meet the ANSI requirements.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation x Provide current year MCP. 9/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers x Provide current tested (not new out of the box) fire extinguisher in the elevator machine room. 9/5/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements 110.11a Need to secure 1st floor sill to floor
MO Minimum : Elevators (H) - Machine Rooms (H)2 Provide code compliant ladder or steps to access elevated machine platform in machine room. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)1 Steps leading up to machine room need to be permanently installed with a handrail to prevent safety hazards
MO Minimum : Elevators (H) - Machine Rooms (H)1 x Provide safe and convenient access to secondary level, proper steps w/handrail. SECOND NOTICE. 9/5/2023
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door shall be self-closing and self-locking. 9/15/2021
MO Minimum : Elevators (I) - Pits (I)1 Remove fluids from the pit. Provide means of waterproofing to prevent further entry of fluids. 9/15/2021
MO Minimum : Elevators (I) - Pits (I)4 x Counterweight buffers are rusted through and broken, will not support elevator. Red tagged, Re-inspection required 1/16/2023
MO Minimum : Elevators (I) - Pits (I)1 Pit has at least 6" of water in it, needs to be kept clean & dry
MO Minimum : Elevators (J) - Counterweights (J)2 Provide spin out cable through the rope shackles on the counterweights
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Governor rope is undersized, needs to be replaced. Re-inspection required 1/16/2023
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 x x Test the car safeties and provide means (tool) to wind up safeties for testing. 5/5/2022
A17.1-2016 : Elevators 2.13 - Governor, Overspeed Switch, and Seal 8.6.4.12 x Need to replace defective governor, not operating properly
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate. 9/15/2021