Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - reinspect x Install proper emergency exit cover. Must be designed to support weight and secured so that it can only be opened from the car top without the use of tools. 12/12/2018
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 x x Test the car safeties and provides means (tool) to wind up safeties for testing. 2/19/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)9 Capacity Plate Provide means for substantially level floor. Pull out hole creates a tripping hazard. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door shall be self-locking and self-closing. 9/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Provide a current tested fire extinguisher in the machine room. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 Wooden stairway treads to access machine and controller are worn and damaged and shall be replaced or repaired as needed. 9/15/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate. 9/15/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 Emergency exit is not code compliant. 9/15/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit light shall work. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Provide code compliant lighting in the machine room (10 FTC minimum). 9/15/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x The governor rope pullout shall be 42" or less. 9/7/2021
MO Minimum : Elevators (I) - Pits (I)1 The debris in the pit shall be removed. The pit shall be kept clean. 9/15/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit lighting shall be operational. 9/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams The car safety key shall be kept on-site. 9/15/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 The emergency exit shall be capable of sustaining a load of 300 lbs. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all material from the machine room which is not required for the operation of maintenance of the elevator. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)1 The wooden steps going up to the machine room deck are damaged and shall be replaced. 9/15/2021
MO Minimum : Elevators (A) - Hoistways (A)16 The exposed wiring on the car top and in the hoistway at the 2nd landing shall be enclosed. 9/15/2021
MO Minimum : Elevators (A) - Hoistways (A)16 All wireway and electrical device covers must be installed. 9/15/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 9/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Provide a current tested ABC fire extinguisher in the machine room. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Provide a minimum of 10 ft candles of illumination measured at the floor through out the machine room 9/27/2021
MO Minimum : Elevators (A) - Hoistways (A)16 Remove exposed wiring and splices from car top and replace with proper NEC wiring 9/27/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Provide MCP. 6/1/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current State Elevator Certificate. 6/1/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Provide existing pit light to work. 6/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)1 Provide safe and convenient access to the elevator machine room, wooden steps leading in are damaged. 6/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)1 First plank into the machine room needs to be secured down. Trip hazard. 6/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 Machine room door shall be self locking / self closing 7/1/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Electrical wiring provided for new cab lighting shall be protected & open splices enclosed in junction boxes per NFPA 70 7/1/2024