Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Wooden stairway treads to access machine and controller are worn and damaged and shall be replaced or repaired as needed. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No The wooden steps going up to the machine room deck are damaged and shall be replaced. 9/15/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No The pit lighting shall be operational. 9/15/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No The pit light shall work. 9/15/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No The governor rope pullout shall be 42" or less. 9/7/2021
MO Minimum : Elevators (A) - Hoistways (A)16 No No The exposed wiring on the car top and in the hoistway at the 2nd landing shall be enclosed. 9/15/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 No No The emergency exit shall be capable of sustaining a load of 300 lbs. 9/15/2021
MO Minimum : Elevators (I) - Pits (I)1 No No The debris in the pit shall be removed. The pit shall be kept clean. 9/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams No No The car safety key shall be kept on-site. 9/15/2021
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)1 Yes Yes Test the car safeties and provides means (tool) to wind up safeties for testing. 2/19/2020
MO Minimum : Elevators (A) - Hoistways (A)16 No No Remove exposed wiring and splices from car top and replace with proper NEC wiring 9/27/2021
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Remove all material from the machine room which is not required for the operation of maintenance of the elevator. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No Provide safe and convenient access to the elevator machine room, wooden steps leading in are damaged. 6/1/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)9 Capacity Plate No No Provide means for substantially level floor. Pull out hole creates a tripping hazard. 9/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation No No Provide MCP. 6/1/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Provide existing pit light to work. 6/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Provide code compliant lighting in the machine room (10 FTC minimum). 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No Provide a minimum of 10 ft candles of illumination measured at the floor through out the machine room 9/27/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Provide a current tested fire extinguisher in the machine room. 9/15/2021
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 No No Provide a current tested ABC fire extinguisher in the machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Provide a current tested ABC fire extinguisher in the machine room. 9/15/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current State Elevator Certificate. 6/1/2024
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self-locking and self-closing. 9/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self locking / self closing 7/1/2024
conversion conversion conversion - reinspect Yes No Install proper emergency exit cover. Must be designed to support weight and secured so that it can only be opened from the car top without the use of tools. 12/12/2018
MO Minimum : Elevators (H) - Machine Rooms (H)1 No No First plank into the machine room needs to be secured down. Trip hazard. 6/1/2024
MO Minimum : Elevators (A) - Hoistways (A)16 No No Exposed wiring and splices on cartop need to be enclosed per NEC.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 No No Emergency exit is not code compliant. 9/15/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting No No Electrical wiring provided for new cab lighting shall be protected & open splices enclosed in junction boxes per NFPA 70 7/1/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Display current state operating certificate. 9/15/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Car would not pick load. Safeties were not set. Need to return when repairs have been made to set safeties to complete 5 year test.
MO Minimum : Elevators (A) - Hoistways (A)16 No No All wireway and electrical device covers must be installed. 9/15/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 9/15/2021