Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 5.11 - Plunger and Cylinder 8.6.5.5 Oil leakage collection device on cylinder head to direct oil into container for measurement is not attached, causing oil to leak off head, not into container, repair same
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Need to repair cab lights. 2/12/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x 2.27.1.1.1 Emergency phone does not work. Dials out and plays recording but gives a disconnected phone line recording. Repair or replace 1/25/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection There is a oil recovery unit installed in the pit of this elevator designed to return the oil leakage from the packing gland on the cylinder head. The State of Missouri has determined that this device does not suffice for oil leakage and is only allowed for temporary use until the packing gland can be repaired/replaced. Remove the recovery unit after the packing gland has been repaired/replaced and record the oil loss per A17.1 2016 - 8.6.5.5.7. Please note that the cylinder diameter of this unit is excessively large and a 5 gallon containment system may not be feasible. Recommend a variance be considered. 1/21/2025