Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)1 Car ventilation fan has a battery and will not run on battery power when power is removed. 4/18/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Need maintenance control program on site posted on controller by or on next test 12/14/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light in car not working 1/4/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems x Door restrictors not working 1/4/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light does not work. 4/18/2022
MO Minimum : Elevators (N) - Guide Rails (N)1 Repair car top slide guides. Inserts completely worn out. 12/1/2020
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 4.2 - Hoistway doors 8.6.4.13 x Safety retainers are missing on top and bottom hoistway doors, need to install safety retainers. Re-inspection required 10/4/2024
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Overspeed valve is unsealed and needs a category 5 full load weight test. Perform full load test within 90 days or less 4/18/2022
conversion conversion n/a Pit must be kept clean 12/1/2020
conversion conversion n/a Standing water on car top needs to be corrected 12/1/2020
conversion conversion n/a Emergency phone not working on emergency power no reinsp required 12/1/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 12/14/2020