MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection)
|
|
|
Car door restrictor does not work and shall be repaired.
|
1/4/2019
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Car top light does not work and shall be repaired.
|
1/4/2019
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
High voltage (110V) wiring on car top shall be enclosed in conduit.
|
1/4/2019
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
Hoistway duct covers shall be installed.
|
1/4/2019
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)1(A)
|
|
|
Suspension rope data tags shall be installed.
|
1/4/2019
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
Pit light does not work and shall be repaired.
|
1/4/2019
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)8
|
|
|
Pit sump pump cover shall be installed flush with the pit floor.
|
1/4/2019
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current state operating certificate shall be posted in the machine room in a non-combustible frame.
|
10/27/2020
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)3
|
|
|
A counterweight guard shall be installed.
|
10/27/2020
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
The machine room door shall be self-locking and self-closing.
|
10/27/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
The machine room fire extinguisher shall be tagged to verify that the extinguisher is current.
|
10/27/2020
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)8
|
|
|
Traveling cables in the machine room shall be enclosed in wireway.
|
10/27/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.7 Signs and Data Plates
|
|
|
A code data plate is required.
|
10/27/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
12/1/2021
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6.5 Fire Extinguishers
|
|
|
A current ABC type fire extinguisher shall be provided in the machine room.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.4.11 Runby (Re-Inspection)
|
x
|
|
Provide code compliant counterweight runby.
|
8/22/2023
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Testing is incomplete. Full load buffer testing, setting the safeties, and no load counterweight buffer test still need to be completed.
|
8/23/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
The in car emergency light shall be operational.
|
9/22/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
The alarm bell shall operate on auxiliary power.
|
9/22/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting)
|
x
|
|
The in car emergency telephone shall be operational.
|
9/22/2020
|
MO Minimum : Elevators
|
(S) - Fire Service
|
211.7 Firefighters Operations/Signage
|
x
|
x
|
Fire service phase 1 instructions shall be posted at the hall key switch, and fire service phase 2 instructions shall be posted in the car.
|
9/22/2020
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
x
|
Fire service phase 1 & phase 2 key switches shall be legible.
|
9/22/2020
|
MO Minimum : Elevators
|
(S) - Fire Service
|
(S)1
|
x
|
x
|
The 3rd landing car call shall be operational on fire service phase 2.
|
9/22/2020
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)1
|
x
|
x
|
Weight related testing of safeties, buffers, and machine brakes shall be completed.
|
11/8/2018
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - Door Systems 8.6.4.13 (Re-Inspection)
|
x
|
|
The door restrictor shall be operational.
|