Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The emergency alarm bell shall be operational. 4/17/2020
A17.1-1996 : Elevators 2.11 - Disconnecting Means and Control 1001.2(b)(11) Label the disconnects with the location, source, and breaker numbers of the panel from which it is fed. 3/17/2023
A17.1-1996 : Elevators 3.13 - Windows, projections, recesses, and setbacks 1001.2(c)(19) There are windows in the hoistway on the 1st and 2nd level. The windows shall be marked in lettering 4" in height that read: "ELEVATOR". The lettering shall be visible from the outside of the building. 3/17/2023
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits The pit needs to be cleaned. Clean the dust, debris, water, and oil from the pit. 3/17/2023
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x The in car emergency lighting shall be operational. 4/17/2020
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 3/17/2023
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures and fire log are missing. 3/17/2023
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. 3/17/2023