Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room
A17.1-1996 : Elevators 1.8 - Door closing force 1001.2(a)(8) x x Door closing force exceeded maximum allowed. RED TAGGED 8/24/2021
A17.1-1996 : Elevators 3.17 - Door and gate equipment 111 Door restrictor out of adjustment. 3/8/2024
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency light shall work, may need battery replacement. 8/24/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone did not provide 2 way communication. May need to be reprogrammed. 8/24/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x emergency phone line not working 6/20/2024
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 One cab light bulb is not working. 2/24/2020
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x OSV is not sealed and must have a cat 5 weight test performed within 90 days or less 8/24/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) x OSV is not sealed or tagged. Perform required test on OSV within 90 days. Re-inspection required
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x OSV unsealed, provide testing. 7/24/2023
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate post current certificate in machine room
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current certificate. 3/8/2024
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(b) Provide current year documents for the MCP. 3/8/2024
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Provide phone to work 7/20/2022
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 The cab light bulbs shall be guarded to contain glass if light breaks. 2/24/2020
A17.1-1996 : Elevators 2.10 - Numbering of elevators, machines, and disconnect switches 1001.2(b)(10) The first floor elevator entrance shall be labeled as "Elevator #1". 2/24/2020
A17.1-1996 : Elevators 1.15 - sign and operating device symbols 1001.2(a)(15) The inside of the cab shall be labeled as "Elevator #1". 2/24/2020
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Unsealed