| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 3.20 - Governor rope | 206.5 | Yes | No | Governor rope is rouged and showing signs of internal damage (replace gov. Cable) | 5/7/2026 |
| A17.1-1996 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 203 | Yes | Yes | Safeties failed to activate | 5/12/2026 |