Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x 2-way communication device shall work, with and without main power, and give proper location. 7/15/2025
MO Minimum : Elevators (H) - Machine Rooms (H)1 Stairs to machine room shall have proper handrail. 9/19/2025
MO Minimum : Elevators (H) - Machine Rooms (H)2 Remove old window-style AC unit, fill void with approved fire-resistant materials. 9/19/2025
MO Minimum : Elevators (H) - Machine Rooms (H)7 Machine room shall have GFCI outlet. Currently standard outlet. 9/19/2025
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light shall work. 9/19/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Current state operating permit shall be displayed in the equipment room in a non-combustible frame. 9/19/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 9/19/2025
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x x Building removed all attached FAID and Fire Panel. Elevator Red Tagged. 7/15/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 9/19/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Compliant/required documentaion shall be kept in equipment room (neat/orginized) including MCP, etc. 9/19/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Suspension rope tail ends shall be properly seized/banned. 9/19/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces Remove sheet metal ducting that is hanging from machine room ceiling. 9/19/2025