Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x 2-way communication device shall work and give proper location. REINSPECTION REQUIRED 60 DAYS 5/6/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Replace damaged phase 2 signage 7/22/2022
MO Minimum : Elevators (I) - Pits (I)1 I(1)/106.1 Pit shall be kept dry. Remove rust from pit equipment , repaint, investigate/repair water leak. Jack casing full of water. Drain, clean, seal. 12/7/2022
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x 1.6 voltage low on phone line will not let phone call out 1/30/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Telephone needs an activated direct line to 24 hr service 11/7/2019
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits x I-1 Mo-Min water in pit sump not working 1/30/2019
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits x pit light not working 1/30/2019