Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
Demarcation light missing on top landing
|
6/12/2023
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.11.4.2.13 Escalator Handrail Safety Systems
|
x
|
|
Provide testing of the escalator handrail speed sensor.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Provide testing, record results.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.1 Escalator Handrails
|
|
|
Right handrail is cracked, needs to be replaced
|
|
A17.1-1996 : Escalators
|
8.12 - Steps, step chains, and trusses
|
802.7
|
|
x
|
Step chains are bad and need to be replaced. Steps do not mesh with each other. Red-tagged
|
12/23/2021
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5.2(i) Demarcation lighting
|
x
|
|
Upper demarcation lights not working.
|
|