Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Platform Lifts CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate A current MO State operating certificate shall be posted on or near the equipment in a noncombustible frame with a clear protective vision plate over it. 6/6/2022
Missouri Minimum : Platform Lifts CSR 40-5.100 State Operating Certificate 5.100(2) display of certificate A current state operating certificate shall be displayed near the lift. 6/6/2022
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 An auxiliary illumination source to provide general illumintion of not less than 2.2lx (0.2fc) and shall use no fewer than 2 lamps of approximately equal wattage shall be provided. Note: 1 or 2 bulbs not working. 5/7/2024
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 (Re-Inspect) x Auxiliary illumination shall operate when power fails, and be capable of operating for at least 4hr. Emergency lighting did not operate with main power removed. 10/23/2025
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display the current state operating certificate. 5/18/2020
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 Electrical wiring shall conform to NFPA70. Wiring "Flex" has pulled out of connector for wiring from disconnect to the unit tower, exposing wiring to damage. 10/23/2025