Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.11 Runby (Re-Inspection) x Shorten Hoist cables counter weights stricking buffer when car is at top landing 1/8/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Repair inoperative emergency Phone
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Emergency light not working. 1/14/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Fireman's emergency service shall be tested. Re-inspection required 10/4/2022
A17.1-1996 : Elevators 2.20 - Winding drum machine and slack cable device 208.1 x Ring and string not working. 4/24/2019
A17.1-1996 : Elevators 3.17 - Door and gate equipment 111 New door gibs need on Floors 16, 17, 19, 21, all rusted through. 7/15/2020
A17.1-1996 : Elevators 3.17 - Door and gate equipment 210.1e Floor 16 needs new pick up rollers. 7/15/2020
A17.1-1996 : Elevators 3.17 - Door and gate equipment 110 Floors 16, 17, 19,21 need new door gibs. The are almost rusted through. 7/15/2020
A17.1-1996 : Elevators 3.23 - Suspension rope 206.7 x x Suspension ropes do not meet minimum requirements, need to be replaced. ELEVATOR RED TAGGED. 10/21/2019
A17.1-1996 : Elevators 3.28 - Counterweight and counterweight buffer 1001.2(c)(13) x Counterweight bracket is missing rings for earthquake ring and string. 10/21/2019
A17.1-1996 : Elevators 3.28 - Counterweight and counterweight buffer 1001.2(c)(13) x Counterweight bracket is missing rings for earthquake ring and string. Test needs to be conducted. 2/21/2020
A17.1-1996 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 201.4h x Counterweight striking buffer when car is at the top ?oor. Shorten hoist cables to meet code parameters.