                        A17.1-1996 : Elevators
                     | 
                    
                        1.5 - Car lighting and receptacles
                     | 
                    
                        204.7
                     | 
                    
                     | 
                    
                     | 
                    
                        Emergency light not working.
                     | 
                    
                        1/14/2019
                     | 
                
                
                    | 
                        A17.1-1996 : Elevators
                     | 
                    
                        2.20 - Winding drum machine and slack cable device
                     | 
                    
                        208.1
                     | 
                    
                            x
                     | 
                    
                     | 
                    
                        Ring and string not working.
                     | 
                    
                        4/24/2019
                     | 
                
                
                    | 
                        A17.1-1996 : Elevators
                     | 
                    
                        3.28 - Counterweight and counterweight buffer
                     | 
                    
                        1001.2(c)(13)
                     | 
                    
                            x
                     | 
                    
                     | 
                    
                        Counterweight bracket is missing rings for earthquake ring and string.
                     | 
                    
                        10/21/2019
                     | 
                
                
                    | 
                        A17.1-1996 : Elevators
                     | 
                    
                        3.23 - Suspension rope
                     | 
                    
                        206.7
                     | 
                    
                            x
                     | 
                    
                            x
                     | 
                    
                        Suspension ropes do not meet minimum requirements, need to be replaced.  ELEVATOR RED TAGGED.
                     | 
                    
                        10/21/2019
                     | 
                
                
                    | 
                        A17.1-1996 : Elevators
                     | 
                    
                        3.28 - Counterweight and counterweight buffer
                     | 
                    
                        1001.2(c)(13)
                     | 
                    
                            x
                     | 
                    
                     | 
                    
                        Counterweight bracket is missing rings for earthquake ring and string.  Test needs to be conducted.
                     | 
                    
                        2/21/2020
                     | 
                
                
                    | 
                        A17.1-1996 : Elevators
                     | 
                    
                        3.17 - Door and gate equipment
                     | 
                    
                        111
                     | 
                    
                     | 
                    
                     | 
                    
                        New door gibs need on Floors 16, 17, 19, 21, all rusted through.
                     | 
                    
                        7/15/2020
                     | 
                
                
                    | 
                        A17.1-1996 : Elevators
                     | 
                    
                        3.17 - Door and gate equipment
                     | 
                    
                        210.1e
                     | 
                    
                     | 
                    
                     | 
                    
                        Floor 16 needs new pick up rollers.
                     | 
                    
                        7/15/2020
                     | 
                
                
                    | 
                        A17.1-1996 : Elevators
                     | 
                    
                        3.17 - Door and gate equipment
                     | 
                    
                        110
                     | 
                    
                     | 
                    
                     | 
                    
                        Floors 16, 17, 19,21 need new door gibs. The are almost rusted through.
                     | 
                    
                        7/15/2020
                     | 
                
                
                    | 
                        MO Minimum : Elevators
                     | 
                    
                        11 CSR 40-5.090 Inspection and Testing
                     | 
                    
                        (3) Testing Procedures (Re-Inspect)
                     | 
                    
                            x
                     | 
                    
                     | 
                    
                        Fireman's emergency service shall be tested. Re-inspection required
                     | 
                    
                        10/4/2022
                     | 
                
                
                    | 
                        MO Minimum : Elevators
                     | 
                    
                        (G) - Maintenance, Repair and Replacements
                     | 
                    
                        8.6.4.11 Runby (Re-Inspection)
                     | 
                    
                            x
                     | 
                    
                     | 
                    
                        Shorten Hoist cables counter weights stricking buffer when car is at top landing
                     | 
                    
                        1/8/2025
                     | 
                
                
                    | 
                        A17.1-1996 : Elevators
                     | 
                    
                        5.2 - Bottom clearance, runby, and minimum refuge space
                     | 
                    
                        201.4h
                     | 
                    
                            x
                     | 
                    
                     | 
                    
                        Counterweight striking buffer when car is at the top ?oor. Shorten hoist cables to meet code parameters.
                     | 
                    
                        7/14/2025
                     | 
                
                
                    | 
                        MO Minimum : Elevators
                     | 
                    
                        (G) - Maintenance, Repair and Replacements
                     | 
                    
                        (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days)
                     | 
                    
                            x
                     | 
                    
                     | 
                    
                        Repair inoperative emergency Phone
                     | 
                    
                        7/14/2025
                     |