Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Testing was incomplete and must have the buffers compressed with weights to complete test. 4/4/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Repair phone so that it will operate in the event of a power outage 1/2/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Fire service shall be tested. Re-inspection required 10/4/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.11 Runby (Re-Inspection) Yes No Shorten Hoist cables counter weights striking buffer when car is at top landing 7/14/2025
A17.1-1996 : Elevators 2.29 - Car and counterweight safeties Table 205.3 Yes Yes When setting the safeties, the car slide is only reaching 19”. The minimum slide for this car is 33”. Repair or replace as needed 4/4/2022