Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(b)(1) No No Provide a copy of the MCP in the machine room. 7/13/2026
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 No No Must provide and maintain Code Data Tag. 8.6.1.6.7 9/9/2026
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1.1.1 Means of Communication (Red Tag) No No Repair the emergency phone as the incoming line is dead. 7/13/2026
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Obtain and display a current state operating certificate in the machine room. 7/13/2026
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes Yes Elevator red tagged due to being 5 years past due inspection. Have elevator inspected, correct all violations and obtain a current state operating certigicate. 7/23/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection No No Must Provide Means to monitor Oil loss from jack packing Gland. 8.5.5.5.2 9/9/2026
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers No No Must provide Annual test tag on Machine room Fire Extinguisher. 8.6.1.6.5 9/9/2026