Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.33 - Tanks 1004.2(b)(16) Have the oil changed as it is very rusty looking and contaminated. maybe it has water in it.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate in the machine room
A17.1-1996 : Elevators 2.36 - Hydraulic Cylinders 1004.2(b)(19) Have the cylinder tested with weights to test for leakage because the oil tank is very low and cannot be accounted for. There is no evidence of oil in the machine room or the pit.
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Repair the emergency phone as there is no dial tone. 4/11/2023
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x Replace the emergency light battery. 4/11/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate in the machine room. 10/20/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate in the machine room 10/20/2023
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Have the emergency phone repaired as there is no dial tone 2/6/2025