Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) vacume up red dust in the machine room--NOTE caution on setting off smoke detectors off in machine room 9/25/2024
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate needs current certificate posted in machine room 9/25/2024
A17.1-1996 : Elevators 2.16 -Overhead Beam and Fastenings 105.3 isolation pads under machine need replaced 6/30/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records MCP shall be kept in equipment room, including Fire service testing log, recorded monthly. no MCP / Fire test log on-site 9/25/2024
A17.1-1996 : Elevators 2.16 -Overhead Beam and Fastenings 105.3 isolation pads under machine need replaced 9/25/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Repair broken pit light cover 9/25/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records G(1)/A17.1-2016:8.6.1.4 :Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) . (2020&2021 VIOLATION) 9/25/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) I(6) Repair broken pit light cover. 2020&2021VIOLATION 9/25/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements G(1)Counterweight Hold-down’s are loose and should be adjusted properly. 9/25/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate in machine room 9/25/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide current MCP in machine room 9/25/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) provide MCP in machine room
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x provide operational phone in cab 11/4/2024
A17.1-1996 : Elevators 3.20 - Governor rope 206.5 x 206.5 : Governor rope shall be shortened for proper alignment of tail sheave 2020&2021VIOLATION (2nd REINSPECTION > 6/27/22; 30 days) 12/28/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x B(11)/1.6.1/2.27.1.1.1-3d : 2-way communication device shall work and give proper location (REINSPECTION 14days to REDTAG) 12/28/2022
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) x 3.23: Ropes replaced(Jan 2020) no rope data tag . 5/27/2022
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) x suspension cables ( red rust or rouge) needs attention-lubrication 9/24/2019
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) x 3.23: Ropes replaced(Jan 2020) no rope data tag . 5/27/2022
A17.1-1996 : Elevators 3.20 - Governor rope 206.5 x 206.5 : Governor rope shall be shortened for proper alignment of tail sheave 5/27/2022