Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) x 1001.2(c)(29)(4) ropes rouging /undersize need replaced 120 days to complete 6/29/2021
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) x 3.23: Ropes replaced, no rope data tag . 5/27/2022
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) x 3.23: Ropes replaced, no rope data tag . 5/27/2022
A17.1-1996 : Elevators 3.20 - Governor rope 1001.2(c)(26) x 5.6.2/ 8.11.2.1.5(g) Governor Rope shall be shortened/replaced to allow proper Tension device clearance. REINSPECTION>6/27/22 12/28/2022
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate current certificate needs to be dis[layed in machine room 6/29/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate in machine room 9/25/2024
conversion conversion n/a Install metal tags for annual & 5 yr safety test to governor 6/29/2021
A17.1-1996 : Elevators 2.16 -Overhead Beam and Fastenings 105.3 isolation pads under machine need replaced 6/29/2021
conversion conversion n/a isolation pads under machine need replaced 6/29/2021
A17.1-1996 : Elevators 2.16 -Overhead Beam and Fastenings 105.3 isolation pads under machine need replaced 6/30/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records MCP shall be kept in equipment room, including Fire service testing log, recorded monthly. no MCP / Fire test log on-site 9/25/2024
conversion conversion n/a needs current certificate posted 6/29/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide current MCP in machine room 9/25/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) provide on site MCP
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x provide operational phone in cab 11/4/2024
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) red dust needs to be vacumed up in machine room NOTE smoke detectors in the machine room 6/29/2021
MO Minimum : Elevators (I) - Pits (I)1 REMOVE LARGE BAG OF TRASH FROM PIT.(all units) 9/25/2024
MO Minimum : Elevators (A) - Hoistways (A)16 REPAIR CARTOP LIGHT WIRING. 9/25/2024
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) x suspension cables (red rust or rouge) needs attention--lubricate 9/24/2019