Missouri Minimum : Platform Lifts
|
(U) - Existing Vertical and Inclined Platform Lifts
|
(U)1 (Re-Inspect)
|
x
|
|
When the bottom landing door is open the lift still operates. The lift shall not be able to operate while a landing door is open.
|
12/11/2023
|
Missouri Minimum : Platform Lifts
|
(U) - Existing Vertical and Inclined Platform Lifts
|
(U)1 (Re-Inspect)
|
x
|
|
Unable to check the relief pressure on this unit as it does not have fitting to attach a gauge on the control valve
|
|
Missouri Minimum : Platform Lifts
|
(U) - Existing Vertical and Inclined Platform Lifts
|
(U)1
|
|
|
There are no " In Case of Fire" signs at either landing.
|
|
Missouri Minimum : Platform Lifts
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) display of certificate
|
|
|
A current MO State operating certificate shall be displayed near the lift.
|
|