Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Yes No Car door restrictor shall operate. 3/2/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems No No Replace the missing door guide(s). 4/2/2026
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes Install and test all smoke detectors and phases of fire service. 2/11/2022
MO Minimum : Elevators (S) - Fire Service (S)1 Yes Yes Install and test all smoke detectors and phases of fire service. 3/2/2023
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Firemans' Phase 1 shall operate. 3/2/2023
A17.1-2016 : Elevators 1.18 - Restricted opening of car or hoistway doors 8.6.4.13.1(l)(Door Restrictor) Yes No The car door restrictor shall be functional. 7/24/2025
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability Yes No Emergency communications loss monitor shall work. 3/26/2024
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability Yes No Emergency communications loss monitor shall work. - Not corrected at time 3/26/24 re-inspection. 1/14/2025
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability Yes No Emergency communications loss monitor shall work. This violation has not been repaired since previous inspection. This is the final notice for this violation. Failure to correct violation immediately may result in elevator being locked out of service until corrected. 7/24/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.2(d) - A 2 hour fire rated machine room door with a self-closing and self-locking door shall be provided. 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.2(I) - An ABC type fire extinguisher shall be provided. 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.2(h) - Code compliant machine room lighting shall be provided. 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.2(h) - A GFI receptacle shall be provided in the machine room. 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.2(k) - Provide proper machine room ventilation. 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.1(d) - Cab flooring shall be installed 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.2(r) - Disconnects shall be installed at proper NEC specifications 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.3(m) - All hoistway duct covers and electrical box covers need to be installed. 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.2(i) - Patch the holes in the machine room walls. 3/2/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (2)(C) Re-Inspection Required to Enforce. Yes No 8.10.3.2.4(b) - Install missing gib on top floor hoistway door. 3/2/2023
A17.1-2016 : Elevators 2.1 - Access to machine space 8.10.3.2.2(d) Yes No A 2 hour fire rated machine room door with a self-closing and self-locking door shall be provided. 2/11/2022
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 8.10.3.2.2(h) Yes No Code compliant machine room lighting shall be provided. 2/11/2022
A17.1-2016 : Elevators 2.3 - Lighting and receptacles 8.10.3.2.2(h) Yes No A GFI receptacle shall be provided in the machine room. 2/11/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation No No A code compliant MCP and related on-site documentation shall be provided in the machine room. Note: No 2022, and 2023 is blank. 4/2/2026
A17.1-2016 : Elevators 2.6 - Ventilation 8.10.3.2.2(k) Yes No Provide proper machine room ventilation. 2/11/2022
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.10.3.2.2(l) Yes No An ABC type fire extinguisher shall be provided. 2/11/2022
A17.1-2016 : Elevators 3.12 - Pipes, wiring, and ducts 2.8 No No Replace missing 4x4 box cover on side hoistway wall at midway point of hoistway. 4/2/2026
A17.1-2016 : Elevators 3.12 - Pipes, wiring, and ducts 2.8 No No 4x4 electrical box on cartop needs to have wiring inside box and cover installed. 4/2/2026
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits No No Pit shall be kept clean. Remove excess debris/oil from pit floor. 4/2/2026
A17.1-2016 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.3.2 Phase I Operation Recall by Initiating Device Yes Yes The fire alarm initiating device at the third landing shall signal the elevator to go into fire service operation. Note: When the device was activated, a building alarm occurred, but the elevator fire service was not initiated. 3/24/2023