MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)1(A) Hoist ropes appear dry and showing "rouge". Ropes shall be cleaned and lubricated per OEM recommendations.
MO Minimum : Elevators (I) - Pits (I)1 Pit shall be kept clean and dry. Remove rust from pit equipment, repair/replace as needed, apply rust prevention treatment to all pit steel, investigate/repair water leak.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (A) - Hoistways (A)13 Outside door at the top of the hoistway needs to be locked at all times. The lock is not operating properly. 7/6/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The outside door at the top of the hoistway shall have signage installed that states: " Danger, Open Elevator Hoistway". 7/6/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 6/15/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. 6/15/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. 6/15/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Install a code data plate. It shall read: Missouri Minimums. 6/15/2022
MO Minimum : Elevators (H) - Machine Rooms (H)2 All machine rooms or enclosures shall have a self-locking and self-closing door and shall be operable from the interior space without the use of a key. 6/15/2022
MO Minimum : Elevators (A) - Hoistways (A)15 Outside door at the top of the hoistway needs to be locked at all times, it shall have a self-locking door and shall be operable from the interior space without the use of a key. The outside of the door shall have signage that shall be installed that states: "Danger, Open Elevator Hoistway". 6/15/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 11/17/2023
MO Minimum : Elevators (A) - Hoistways (A)13 Patch the holes in the hoistway. 3/26/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be displayed in the elevator machine room. 3/26/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 3/26/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x x Counterweight buffer spring compromised by water/rust damage. Fell over. Reinspection required to return to service. Elevator Red Tagged. 4/15/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts x Pit channel (car side) compromised by water/rust damage. Replace channel. 4/15/2024