Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.14 Escalator Entrance and Egress Ends
|
|
|
Balustrade panel gaps on both sides exceeds 5 mm needs correcting
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5 Escalator or Moving Walk Startup
|
|
|
Left side balustrade molding bowed out needs to be reattached
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5 Escalator or Moving Walk Startup
|
|
|
Lower machine space cover switch not working
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.11.5 Escalator or Moving Walk Startup
|
|
|
Lower right hand side bulstrade has hole worn through Red tagged out of service
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
Lower right hand skirt panel must be flush (broke indexing tool when tested needs step indexing performed to complete test
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.4 Escalator Combplates
|
|
|
lower right side comb plate has 2 teeth missing adjacent to each other
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.1.4 Maintenance Records
|
|
|
needs maintenance control program on site and posted on controller unit needs to be cleaned down
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(H)
|
|
|
Repair top demarcation light.
|
1/17/2019
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.4 Escalator Combplates
|
|
|
Upper comb plates 3 plates each missing one tooth
|
|