Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(L) Need to replace handrail guides on both sides at top of escalator.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(L) Replace handrail guides on both sides at top of escalator.
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.8 - Deck barricades and antislide devices 8.6.8.11 Anti slide device missing center
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.19 - Maintenance records 8.6.1.4 Need maintenance control program on site posted on controller
A17.1-2016 : Elevators 7.15 - Balustrades 8.11.4.1(o) Screws holding bulstrade molding have to be flushed
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 8.6.8.14 Machine space cover switch not working
A17.1-2016 : Elevators 7.15 - Balustrades 8.11.4.1(o) Balustrade panels must be flushed
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators 7.6 - Caution Signs 6.1.6.9 Caution signage bottom left needs replacing
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(F) Many balustrade panels need to be aligned correctly
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.3 Step/Skirt Performance Index x Need to perform step indexing test. Re-inspection required
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(A) x Failed brake torque test. Red tagged unit. 8/5/2019