A17.1-2016 : Elevators
|
7.15 - Balustrades
|
8.11.4.1(o)
|
|
|
Balustrade panels must be flushed
|
|
A17.1-2016 : Elevators
|
7.15 - Balustrades
|
8.11.4.1(o)
|
|
|
Screws holding bulstrade molding have to be flushed
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
8.6.8.14
|
|
|
Machine space cover switch not working
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.6 - Caution Signs
|
6.1.6.9
|
|
|
Caution signage bottom left needs replacing
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.8 - Deck barricades and antislide devices
|
8.6.8.11
|
|
|
Anti slide device missing center
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.19 - Maintenance records
|
8.6.1.4
|
|
|
Need maintenance control program on site posted on controller
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(A)
|
|
x
|
Failed brake torque test. Red tagged unit.
|
8/5/2019
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(L)
|
|
|
Need to replace handrail guides on both sides at top of escalator.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(L)
|
|
|
Replace handrail guides on both sides at top of escalator.
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
(T)2(F)
|
|
|
Many balustrade panels need to be aligned correctly
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Need to perform step indexing test. Re-inspection required
|
|