Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Demarcation lights out top & bottom 1/17/2019
conversion conversion n/a Top right comb plate missing 1/17/2019
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(B) Replace bad key switch. 1/17/2019
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(L) Replace handrail guides on both sides at the top of escalator.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(H) Repair both top and bottom demarcation lights.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.1.4 Maintenance Records Need maintenance control program on site and posted on controller
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5 Escalator or Moving Walk Startup Screws on balustrade trim have to be flushed smooth cannot protrude as snag hazard
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.11.5.2(i) Demarcation lighting x Upper and lower demarcation lights not working 6/1/2021
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.14 Escalator Entrance and Egress Ends Machine space covers top and bottom rendered unoperateable
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(D) Replace broken step tread
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(F) Repair or replace damaged balustrade panel (top right side) also several other panels need to be aligned correctly
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.11.4.2.10 Escalator Missing Step or Pallet Device x x Missing step switch does not work. Red-tagged and removed from service. Re-inspection required
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.3 Step/Skirt Performance Index x Need to perform step indexing test. Re-inspection required
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide a maintenance control program