Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Post current State Certificate in machine room 10/7/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements The car top inspection light/fixture did not operate. Repair fixture/light for proper operation and illumination for maintenance/emergency personnel. 10/7/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing OSV is not sealed. Need to be full load tested. 10/15/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.1 Examination and Maintenance x Hydraulic cylinder packing is leaking excessively and needs replacing. Re-inspection required 11/23/2022
conversion conversion conversion - red tag x x Complete annual Test with Full Load to verify jack is not leaking 7/7/2017