A17.1-1996 : Escalators
|
7.7 - Combplate and comb step impact device
|
1206.6
|
|
|
Comb impact guides are rusted. Pressure test on tripping pressure needed. Reinspect within 30 days.
|
3/29/2023
|
A17.1-1996 : Escalators
|
8.12 - Steps, step chains, and trusses
|
1206.6
|
|
|
Step demarcation strip is broken on a couple steps
|
6/28/2022
|
A17.1-1996 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
1206.6a
|
|
|
Clean escalator truss space.
|
3/29/2023
|
A17.1-2016 : Elevators
|
9.19 - Maintenance Records
|
8.6.1.4.1(a)(1)
|
|
|
Record maintenance, call backs, repairs, and testing in MCP and provide location of MCP on Escalator controller
|
|
A17.1-2016 : Elevators
|
9.19 - Maintenance Records
|
8.6.1.4.1(d)
|
|
|
Record Step/Skirt Indexing Graph for 2025 in MCP.
|
|
A17.1-1996 : Escalators
|
7.3 - Handrails
|
802.2
|
|
|
Replace left cracked handrail.
|
7/2/2020
|
A17.1-1996 : Escalators
|
7.3 - Handrails
|
802.2
|
|
|
Repair left handrail that is cracked.
|
3/29/2023
|
A17.1-1996 : Escalators
|
7.16 - Ceiling intersection guards
|
802.3g
|
|
|
Replace wrong ceiling intersection guards with correct one.
|
7/2/2020
|
A17.1-1996 : Escalators
|
8.13 - Handrail systems and safety devices
|
802.4
|
|
|
Replace main handrail drive chain
|
|
A17.1-1996 : Escalators
|
7.9 - Steps and upthrust device
|
802.5
|
|
|
Replace broken step demarcation strip.
|
3/29/2023
|
A17.1-1996 : Escalators
|
7.7 - Combplate and comb step impact device
|
802.6
|
|
|
Replace broken step demarcations.
|
7/2/2020
|
A17.1-1996 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
806
|
|
|
Provide operating light at top end on unit.
|
|
conversion
|
conversion
|
n/a
|
|
|
Repair inoperative top demarcation light.
|
1/7/2019
|
conversion
|
conversion
|
n/a
|
|
|
Realign outter deck to close 1 inch gap in upper seam.
|
1/7/2019
|
conversion
|
conversion
|
n/a
|
|
|
comb impact guides are rusted and need to be tested to insure proper impact calibration.
|
1/7/2019
|