A17.1-1996 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
1206.6a
|
|
|
Clean escalator truss space.
|
3/29/2023
|
|
A17.1-1996 : Escalators
|
7.7 - Combplate and comb step impact device
|
1206.6
|
|
|
Comb impact guides are rusted. Pressure test on tripping pressure needed. Reinspect within 30 days.
|
3/29/2023
|
|
A17.1-1996 : Escalators
|
7.8 - Deck barricades and antislide devices
|
802.3i
|
|
|
Missing deck barricades in the center of the two escalators
|
6/28/2022
|
|
A17.1-1996 : Escalators
|
7.7 - Combplate and comb step impact device
|
802.6
|
|
|
Replace broken step demarcations.
|
7/2/2020
|
|
A17.1-1996 : Escalators
|
7.3 - Handrails
|
802.2
|
|
|
Replace left and right side handrail
|
8/26/2025
|
|
A17.1-1996 : Escalators
|
7.16 - Ceiling intersection guards
|
802.3g
|
|
|
Replace wrong ceiling intersection guards with correct ones.
|
7/2/2020
|
|
A17.1-1996 : Escalators
|
8.12 - Steps, step chains, and trusses
|
802.7
|
|
|
Tighten main step drive chain
|
8/26/2025
|
|
A17.1-1996 : Escalators
|
7.5 - Lighting
|
805.7
|
|
|
Top demarcation light fixture failed to illuminate, repair or replacement is required.
|
8/7/2024
|
|
A17.1-1996 : Escalators
|
7.5 - Lighting
|
805.7
|
|
|
Top demarcation light fixture failed to illuminate, repair or replacement is required.
|
8/7/2024
|
|
A17.1-1996 : Escalators
|
8.4 - Drive machine and brake
|
804
|
x
|
x
|
Escalator brake torque when tested was at 82lbs, the maximum torque for this unit is 75lbs. Readjust brake torque to be within limits. No red tag issued at this time, reinspection is required.
|
3/4/2024
|
|
A17.1-2016 : Elevators
|
2.5 - Housekeeping
|
8.6.4.8 Machine Room and Machinery Space
|
|
|
Perform Annual Clean Down of Escalator
|
8/26/2025
|
|
A17.1-2016 : Elevators
|
9.19 - Maintenance Records
|
8.6.1.2.1(a)
|
|
|
Record maintenance, call backs, repairs and testing in MCP and provide location of MCP on controller
|
8/26/2025
|
|
A17.1-2016 : Elevators
|
9.19 - Maintenance Records
|
8.6.1.4.1(d)
|
|
|
Record Step/Skirt Indexing Graph of 2025 indexing in MCP
|
8/26/2025
|
|
conversion
|
conversion
|
n/a
|
|
|
Comb impact guides are rusted and need to be tested to insure proper impact calibration.
|
1/7/2019
|
|
conversion
|
conversion
|
n/a
|
|
|
Install top inner deck card
|
1/7/2019
|
|
conversion
|
conversion
|
n/a
|
|
|
Secure outer deck card.
|
1/7/2019
|
|
conversion
|
conversion
|
n/a
|
|
|
Top and bottom left and right end cap weather seal missing.
|
1/7/2019
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
Step index testing failed, readjust skirt to perform within tolerance, Reinspection is required.
|
8/13/2024
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
x
|
|
Step index testing failed, readjust skirt to perform within tolerance, Reinspection is required.
|
3/4/2024
|