Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No no cirt displayed
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No no current cirt. displayed
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No no current cirt. displayed
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No no current cirt displayed
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emg phone not working no power to phone
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emg phone not working no answer 2/4/2025
MO Minimum : Elevators (I) - Pits (I)1 No No pit has oil an water on floor needs to be cleaned up
MO Minimum : Elevators (I) - Pits (I)1 No No pit floor has oil an water on it
MO Minimum : Elevators (I) - Pits (I)1 No No pit has oil an debris on floor needs to be cleaned
MO Minimum : Elevators (I) - Pits (I)1 No No pit needs to be cleaned oil an water on floor
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No material not related to elev operation stored in mach. room
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No mach. room is being used for storage of non elev related materials
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No leaking sewer pipe in mach room thru hole in celing 6/11/2020
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No repair drop celing or gutter all exposed water lines
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No Remove debris from mach room not elev relaed
MO Minimum : Elevators (H) - Machine Rooms (H)4 No No mach room floor needs to be cleaned up
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No pipes carrying liquid exposed by drop ceiling needing repair
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No emg phone not working no one answered 3/26/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No emg. phone not working 4/14/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No emg phone not working 3/20/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) No No mcp not current