Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.18 - Restricted opening of car or hoistway doors 8.11.3.1.1(r) x Adjust car door restrictor to restrict the opening of the car door outside of the unlocking zone. 12/6/2022
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x emg. phone not working 1/10/2023
A17.1-2016 : Elevators 2.31 - Relief Valves 3.19.4.2 3.19.4.2.1(c) Relief valve shall be sealed.
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Operating Certificate not available. 8.1.4.15 Emergency Telephone Violation noted on 12/6/22 has been corrected.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate current cirt not displayed