Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 6/28/2023
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room. 7/27/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Car emergency lighting shall work. 7/16/2019
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone shall be operational. 4/3/2025
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 102.1 Holes in the machine room wireway shall be covered. 7/27/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x In car emergency telephone shall work. 6/5/2019
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.7 Firefighter' Service Operating Procedures Phase 2 firefighters operation instructions shall be legible. 7/27/2020
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 Pit shall be kept clean and dry. Water shall be removed from pit floor. 4/3/2025
A17.1-1996 : Elevators 1.12 - Car enclosure 204 The car, riding directional indicator lantern is missing, resulting in exposed wiring. The lantern shall be replaced and wires shall be enclosed. 7/27/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x The in car emergency telephone shall be operational. 7/31/2020
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1 The pit shall be kept clean and dry. 6/28/2023
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. 6/28/2023
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Up to date operating certificate is required in the machine room. 6/28/2023