MO Minimum : Elevators (I) - Pits (I)7 Provide pit switch in elevator pit, accessible from the landing door.
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.18.3 Key-Operated Switches No key operated switches installed at landings
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Emergency Light not working. 11/15/2018
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.8.3 Clearance Between Hoistway Doors and Car Doors or Gates x x No spacer installed to provide correct safe distance between hoistway door and car door. 10/12/2022
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.7.2 Clearance Between Hoistway Doors and Landing Sills x x Spacers not installed to provide correct safe distance between hoistway landing door and sill. 10/12/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light not working. Bulbs 9/12/2024