Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 (Re-Inspect) x x Vertical platform drive belt has failed, repair and replacement required. Reinspection before unit can be returned to service. 11/12/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Vertical platform lift inspection could not be performed due to the drive belt failure, reinspection is required. 11/12/2024
ASME A18.1-2005 : Lifts & Chairlifts 2.4 - Driving Machine Brakes 2.4.1 Screw drive machine needs maintenance (screeching noise). 12/18/2020