Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.5 - Housekeeping 8.11.3.1.2(h) Clean Machine room 5/20/2021
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 No do not use elevator in case of fire signs 5/20/2021
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(e) No Maintenance records 7/27/2023
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2 On-Site Documentation No Records 3/9/2022
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4 Instructions for Locating Maintenance Records No records 5/20/2021
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) No wiring diagram's 7/27/2023
A17.1-2016 : Elevators 1.15 - sign and operating device symbols 8.6.1.6.7 Phase II key switch required to replaced-has no halo 5/20/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Pit has scavenger pump required to be removed 5/20/2021
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post updated certificate 5/20/2021
A17.1-2016 : Elevators 2.4 - Machine space 8.6.4.8 Machine Room and Machinery Space Remove unauthorize material 5/20/2021