Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Repair non working lighting in machine room, possible bad bulbs
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Provide current fire extinguisher in machine room
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Re-fasten hoist rope drip pan on top of elevator cab
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) A written MCP shall be kept in the elevator machine room for each elevator
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.11.1.4(b)(2) Hydraulic elevators Placed out of Service x x Elevator placed out of service because full load test was not done as planned. Call to Charles Brinkmann confirmed decision to do so. 9/30/2020
MO Minimum : Elevators (A) - Hoistways (A)13 Enclose hoistway wall at basement level. 10/27/2020
MO Minimum : Elevators (A) - Hoistways (A)15 Guard hoistway window. 10/27/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency phone and emergency light do not work. 10/27/2020
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Light ray active on fire recall. 10/27/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Pit light inoperative. 10/27/2020
MO Minimum : Elevators (S) - Fire Service (S)1 x x Cab fire service light inoperative. Elevator remains out of service due to numerous issues. 10/27/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency light & alarm in car shall work on auxiliary power. Re-inspection reuired 3/23/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be properly displayed in machine space 12/28/2023