MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
|
MO Minimum : Elevators
|
(J) - Counterweights
|
(J)1
|
|
|
Add counterweight to car gate to maintain full open.
|
10/2/2018
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)2
|
x
|
|
All electric elevators shall have final limit switches installed at the top of the hoistway and the bottom of the hoistway.
|
9/17/2021
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4.1(a) On-Site Maintenance Records (MCP Records)
|
|
|
All onsite documents shall be provided in machine room.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
Clean up oil and grease from floor and bed plate
|
10/2/2018
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
The elevator pit light did not work on the day of inspection, repair for proper illumination of the pit floor.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
There is an excessive amount of oil and grease on the machine room floor and bed plate. The oil and grease shall be cleaned up and a catch pan installed to minimize a potential hazard.
|
|
MO Minimum : Elevators
|
(F) - Electrical Switches
|
(F)2
|
x
|
|
Unit shall have bottom final limit switch.
|
|