Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements The car traveling cable, underneath the car, has rubbed through the outer insultation in a couple of locations as the car reaches the lobby. Confirm that no internal wire have been affected and repair or replace the traveling cable. 5/18/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency bell does not work when power is lost. 5/6/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Provide MCP. 4/15/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Provide working code compliant emergency lights,bell ok.. 4/4/2023
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Provide working pit light. 4/15/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Inspection incomplete, the annual inspection could not be complted due to the elevator breaking down during the inspection. Need to complete the following to complete inspection: stop ring relief pressure testing, 15 minute standing test, emergency lighting, alarm & phone & door pressures. Re-inspection required 5/23/2025
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 x OSV is due for testing, provide. 7/8/2024