Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.4 Escalator Combplates The bottom comb plate has a missing tooth and shall be replaced.
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.2 Escalator Step-to-Skirt Clearance x Step indexing is required to be performed. 6/3/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks 8.6.8.2 Escalator Step-to-Skirt Clearance x Step indexing is required to be performed. 6/25/2025
A17.1-2016 : Elevators 8.5 - Speed governor 8.6.8.15.5 x x The speed governor cannot activate as designed and shall be repaired/replaced. Escalator is taken out of service with a red tag issued. 6/3/2025
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(L) A ceiling intersection guard is required on the left side of the escalator to prevent a pinch point for passengers
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(L) A ceiling intersection guard is required on the left side of the escalator to prevent a pinch point for passengers
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(L) A ceiling intersection guard is required on the left side of the escalator to prevent a pinch point for passengers
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(L) A ceiling intersection guard is required on the left side of the escalator to prevent a pinch point for passengers
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(J) A stop switch shall be provided in each machinery space where means of access to the space is provided. The switch when opened shall cause electric power to be removed from the escalator driving-machine motor and brake. The switch shall be of the manually opened and closed type and shall be marked “STOP.”
Missouri Minimum : Escalators (T) - Existing Dumbwaiters, Escalators and Moving Walks (T)2(J) A stop switch shall be provided in each machinery space where means of access to the space is provided. The switch when opened shall cause electric power to be removed from the escalator driving-machine motor and brake. The switch shall be of the manually opened and closed type and shall be marked “STOP.”
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The testing has not been completed on the escalator, need to perform the following test to complete: The interior space shall be inspected. Re-inspection required 6/25/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The testing has not been completed on the escalator at this time. The interior space shall be inspected before the inspection is completed. 5/22/2025
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The testing has not been completed on the escalator at this time. The interior space shall be inspected before the inspection is completed. 6/3/2025