A17.1-1996 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
107.1a
|
x
|
|
Install non-removable means to mechanically hold the elevator above the pit floor to provide safe refuge. The blocking device shall be capable of being operated without complete bodily entry. A17.1 1996 2500.8b
|
9/25/2023
|
A17.1-1996 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
107.1a
|
x
|
|
Install mechanical means to hold elevator above the pit floor. It shall be non-removable and operated without complete bodily entry. (second notice)
|
10/1/2024
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone does not connect. Phone needs to be reprogrammed
|
5/18/2023
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.7 Firefighter' Service Operating Procedures
|
|
|
Post firefighter operating instructions on car operating panel
|
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.7 Firefighter' Service Operating Procedures
|
|
|
Post firefighter operating instructions inside the elevator
|
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.7 Firefighter' Service Operating Procedures
|
|
|
Post firefighter operating instructions on car operating panel
|
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.7 Firefighter' Service Operating Procedures
|
|
|
Post firefighter operating instructions on car operating panel
|
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.8 Switch Keys
|
|
|
All elevators in the same building shall use the same key for firefighter operation
|
9/26/2022
|
A17.1-1996 : Elevators
|
2.14 - Code data plate
|
215
|
|
|
Post code data plate on controller or disconnect
|
|
A17.1-1996 : Elevators
|
2.14 - Code data plate
|
215
|
|
|
Post code data plate on controller or disconnect
|
|
A17.1-1996 : Elevators
|
2.14 - Code data plate
|
215
|
|
|
Post code data plate on controller or disconnect. "ASME A17.1 1996"
|
|
A17.1-1996 : Elevators
|
2.14 - Code data plate
|
215
|
|
|
Post code data plate on controller or disconnect. "ASME A17.1 1996"
|
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
State operating certificate not displayed
|
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
State operating certificate not displayed in machine room
|
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current operating certificate inside machine room
|
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current state operating certificate inside the machine room
|
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.1(a)
|
|
|
Post emergency evacuation of passengers form inside machine room
|
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.1(a)
|
|
|
No maintenance control plan in machine room
|
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.4.1(a)(1)
|
|
|
No maintenance records log in machine room
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.11.1 Firefighters’ Emergency Operation Documentation
|
|
|
Test and log firefighter operation monthly
|
|
A17.1-2016 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
8.6.11.1 Firefighters’ Emergency Operation Documentation
|
|
|
Test and log firefighter operation monthly
|
|
A17.1-2016 : Elevators
|
3.23 - Suspension Means
|
8.6.3.2 (Re-Inspection)
|
x
|
|
Replace damaged suspension ropes due to excessive wire breaks.
|
5/18/2023
|
A17.1-2016 : Elevators
|
3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing
|
8.6.5.10
|
x
|
|
Shorten suspension ropes to maintain proper top runby
|
10/1/2024
|
A17.1-2016 : Elevators
|
2.31 - Relief Valves
|
8.6.5.14.1
|
|
x
|
Perform pressure relief test
|
9/26/2022
|
A17.1-2016 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
8.6.5.14.3(c)
|
x
|
x
|
Car safety did not stop the elevator when governor was tripped. Red Tag
|
5/18/2023
|
A17.1-2016 : Elevators
|
5.15 - Overspeed Valve
|
8.6.5.16.5
|
x
|
|
Overspeed valve operated correctly but the valve adjustment setting needs to be sealed.
|
9/25/2023
|
A17.1-2016 : Elevators
|
5.15 - Overspeed Valve
|
8.6.5.16.5
|
|
x
|
Perform overspeed valve test
|
9/26/2022
|
A17.1-2016 : Elevators
|
5.15 - Overspeed Valve
|
8.6.5.16.5 Over Speed Valve (Red Tag)
|
x
|
x
|
Overspeed valve does not stop the elevator. Red Tag
|
5/18/2023
|
A17.1-2016 : Elevators
|
2.36 - Hydraulic Cylinders
|
8.6.5.5.2 Collection of Oil Leakage
|
|
|
Install cylinder drain line and pit collection container.
|
|
A17.1-2016 : Elevators
|
2.36 - Hydraulic Cylinders
|
8.6.5.5.2 Collection of Oil Leakage
|
x
|
|
Install cylinder drain line. Drain line shall run to it collection container.
|
9/26/2022
|
A17.1-2016 : Elevators
|
2.36 - Hydraulic Cylinders
|
8.6.5.5.2 Collection of Oil Leakage
|
|
|
Install drain line from cylinder head to pit collection container
|
|